{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.morvs.ai/api/v1/osha/sir/check?name=BECTON%20DICKINSON","name":"BECTON DICKINSON","_source":{"data_provider":"AI Analytics","brand_name":"MORVS","brand_url":"https://morvs.ai/","data_provider_url":"https://api.morvs.ai","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-11-19T07:52:56.624Z"},"summary":{"total_severe_injuries":16,"amputations":10,"hospitalizations":9,"eye_losses":0},"top_body_parts":[{"body_part_title":"Fingertip(s)","n":6},{"body_part_title":"Hip(s)","n":3},{"body_part_title":"Finger(s), fingernail(s), n.e.c.","n":3},{"body_part_title":"Multiple body parts, n.e.c.","n":1},{"body_part_title":"Lower leg(s)","n":1},{"body_part_title":"Hand(s), unspecified","n":1},{"body_part_title":"Finger(s), fingernail(s), unspecified","n":1}],"recent_reports":[{"id":"2015096835","event_date":"9/17/2015","employer":"Becton Dickinson","city":"BROKEN BOW","state":"NEBRASKA","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was threading a new roll of bags into the midstream bagger machine. The jaws of the machine include a heat seal and cutters. The machine activated and the jaws caught his finger resulting in the amputation of the left index fingertip.","canonical_url":"https://api.morvs.ai/workplace-injury/2015096835"},{"id":"2023098401","event_date":"9/12/2023","employer":"Becton, Dickinson and Company","city":"BROKEN BOW","state":"NEBRASKA","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Caught in running equipment or machinery, n.e.c.","final_narrative":"An employee had been operating a machine. They were testing the belt tension beneath the machine when their left thumb became caught between the belts and pulleys of the machine. The employee sustained a distal thumb amputation.","canonical_url":"https://api.morvs.ai/workplace-injury/2023098401"},{"id":"2023087564","event_date":"8/18/2023","employer":"Becton Dickinson","city":"BROKEN BOW","state":"NEBRASKA","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was inspecting trays as they came out of the descrambler machine. The employee went to reach for a damaged tray when his right index finger was caught between the tray and a sidepiece of the conveyor line, resulting in a fingertip amputation.","canonical_url":"https://api.morvs.ai/workplace-injury/2023087564"},{"id":"2020087729","event_date":"8/15/2020","employer":"Becton Dickinson and Company","city":"CANAAN","state":"CONNECTICUT","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Puncture wounds, except gunshot wounds","body_part_title":"Hand(s), unspecified","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"On August 15, 2020, an employee was unjamming the rotating diverter wheel on a production machine. The tension released, pushing the employee's hand into a compressed air jet. The air punctured her hand and she was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/2020087729"},{"id":"2019076947","event_date":"7/10/2019","employer":"Becton Dickinson","city":"BROKEN BOW","state":"NEBRASKA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Heat (thermal) burns, unspecified","body_part_title":"Multiple body parts, n.e.c.","event_title":"Contact with hot objects or substances","final_narrative":"Two employees were removing a screw from a high-speed injection molding machine. As they were removing the screw tip, pressurized molten plastic was released through an opening around the screw tip which resulted in both employees being burned by the molten plastic. They sustained burns to the forehead, right neck, face, right arm, and right hand. One employee was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/2019076947"},{"id":"2018066449","event_date":"6/28/2018","employer":"BECTON DICKINSON","city":"COLUMBUS","state":"NEBRASKA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was troubleshooting the conveyor and severed the distal tip of his right index finger when his right hand contacted the chain and gear.","canonical_url":"https://api.morvs.ai/workplace-injury/2018066449"},{"id":"2015041818","event_date":"4/7/2015","employer":"Becton, Dickinson and Company","city":"COLUMBUS","state":"NEBRASKA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was troubleshooting an assembly line in the needle assembly area. When he bent over to look at the bottom of the machine, he rested his hand on a guard on the belt assembly. His finger overlapped with the edge of the guard, tripping a motion sensor that activated the machine push bar. His right-hand middle finger got caught between the push bar and the machine.","canonical_url":"https://api.morvs.ai/workplace-injury/2015041818"},{"id":"2021032614","event_date":"3/28/2021","employer":"Becton, Dickinson and Company","city":"MADISON","state":"GEORGIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Lower leg(s)","event_title":"Part of occupant s body caught between vehicle and other object in nonroadway transport incident","final_narrative":"An employee was driving a stand-up forklift toward a warehouse. The forklift struck a cardboard pallet while turning, and his left leg was caught between the forklift and the pallet. He suffered a broken left tibia and was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/2021032614"},{"id":"2017032743","event_date":"3/26/2017","employer":"Becton, Dickinson and Company","city":"CANAAN","state":"CONNECTICUT","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Hip(s)","event_title":"Fall on same level due to tripping over an object","final_narrative":"An employee was walking past a wooden pallet when she tripped over it and fell to the floor, fracturing her hip.","canonical_url":"https://api.morvs.ai/workplace-injury/2017032743"},{"id":"2022021781","event_date":"2/25/2022","employer":"Becton Dickinson Co.","city":"HOLDREGE","state":"NEBRASKA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Caught in or compressed by equipment or objects, unspecified","final_narrative":"An employee was performing a visual inspection of the pulley cables in the penthouse above sterilization. The employee used a paper towel to assist in checking for burrs and defects in the cable by folding and positioning the paper towel around the three cables of the pulley system. The paper towel caught on the cable, pulling the employee's right hand into the pulley and causing a partial amputation of the little finger (distal phalange) and an avulsion injury to the ring finger.","canonical_url":"https://api.morvs.ai/workplace-injury/2022021781"},{"id":"20201211560","event_date":"12/9/2020","employer":"Becton Dickinson & Co.","city":"HOLDREGE","state":"NEBRASKA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Hip(s)","event_title":"Fall on same level due to tripping over an object","final_narrative":"An employee tripped on a step stool and fell to the floor, suffering a broken hip.","canonical_url":"https://api.morvs.ai/workplace-injury/20201211560"},{"id":"20171010130","event_date":"10/22/2017","employer":"Becton, Dickinson and Company","city":"CANAAN","state":"CONNECTICUT","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Hip(s)","event_title":"Fall on same level due to tripping over an object","final_narrative":"An employee was working with a material handling system on an injection molding press and moving boxes of plastic components. She turned to move and her foot caught the leg of a table, causing her to lose her balance and fall to the floor. She broke her hip.","canonical_url":"https://api.morvs.ai/workplace-injury/20171010130"},{"id":"2015107916","event_date":"10/22/2015","employer":"Becton Dickinson & Co.","city":"HOLDREGE","state":"NEBRASKA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was clearing a jam and jogging the equipment due to a \"barrel trip gate fault.\"  The operator noticed a large jam and entered a gloved finger into the point of operation to clear the jam while jogging the machine.  The left index finger was caught in the dial (part of the machine that brings the plunger up into the barrel for assembly of the syringe) and the fingertip was amputated.  There are interlock doors on the machine normally guarding this point of operation, but the interlocks did not prevent the machine from functioning in the jog mode with the doors open.  The jog function is controlled by a two-button control that is operated from the handheld pendent hardwired to the machine.  Both job buttons can be operated with the same hand.","canonical_url":"https://api.morvs.ai/workplace-injury/2015107916"},{"id":"2015107621","event_date":"10/13/2015","employer":"Becton Dickinson & Co.","city":"HOLDREGE","state":"NEBRASKA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was troubleshooting a form fill and seal machine. When the machine inadvertently cycled, the employee's right index finger was amputated above the first joint.","canonical_url":"https://api.morvs.ai/workplace-injury/2015107621"},{"id":"2019010154","event_date":"1/6/2019","employer":"Becton Dickinson","city":"MOBILE","state":"ALABAMA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was troubleshooting a packaging machine and adjusting the media when his left index finger was caught in the perforation blade, resulting in a traumatic amputation of the distal phalanx.","canonical_url":"https://api.morvs.ai/workplace-injury/2019010154"},{"id":"2015010759","event_date":"1/23/2015","employer":"Becton Dickinson","city":"BROKEN BOW","state":"NEBRASKA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"Maintenance employee was responding to a jammed machine on line #9.  The employee reached into the machine to remove the jam. The machine cycled, feeding another tray that pinched his right ring fingertip between the tray and the frame of the machine, resulting in the tip being amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/2015010759"}]}