{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.morvs.ai/api/v1/osha/sir/check?name=First%20Quality","name":"First Quality","_source":{"data_provider":"AI Analytics","brand_name":"MORVS","brand_url":"https://morvs.ai/","data_provider_url":"https://api.morvs.ai","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-11-02T18:58:15.173Z"},"summary":{"total_severe_injuries":18,"amputations":9,"hospitalizations":11,"eye_losses":0},"top_body_parts":[{"body_part_title":"Fingertip(s)","n":6},{"body_part_title":"Nonclassifiable","n":2},{"body_part_title":"Finger(s), fingernail(s), unspecified","n":2},{"body_part_title":"Finger(s), fingernail(s), n.e.c.","n":2},{"body_part_title":"Rib(s), oblique area","n":1},{"body_part_title":"Knee(s) and leg(s)","n":1},{"body_part_title":"Knee(s)","n":1},{"body_part_title":"Hand(s), unspecified","n":1}],"recent_reports":[{"id":"2021097964","event_date":"9/16/2021","employer":"First Quality Tissue, LLC","city":"LOCK HAVEN","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Knee(s)","event_title":"Fall on same level due to slipping","final_narrative":"An employee slipped and fell on a wet spot of the floor created by condensation on overhead ductwork. The employee suffered a broken right patella and was admitted into the hospital.","canonical_url":"https://api.morvs.ai/workplace-injury/2021097964"},{"id":"2020098780","event_date":"9/16/2020","employer":"First Quality Enterprises, Inc.","city":"KING OF PRUSSIA","state":"PENNSYLVANIA","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was troubleshooting and adjusting the position of a lift table assembly  inside a bagging machine when the entire lift table assembly rotated, pinching the employee's left index finger between the pivot arm and the servo coupling. The employee suffered a partial amputation to the left index fingertip.","canonical_url":"https://api.morvs.ai/workplace-injury/2020098780"},{"id":"2017087742","event_date":"8/13/2017","employer":"First Quality Enterprises","city":"MC ELHATTAN","state":"PENNSYLVANIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was running a pallet destacker when it jammed. He used a pry bar to free it. When it unjammed, his right index finger was caught between the pry bar and the wood pallets, amputating his fingertip without bone loss.","canonical_url":"https://api.morvs.ai/workplace-injury/2017087742"},{"id":"2019076914","event_date":"7/9/2019","employer":"First Quality Tissue, LLC","city":"LOCK HAVEN","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Cuts, lacerations","body_part_title":"Knee(s) and leg(s)","event_title":"Struck by swinging or slipping object, other than handheld, n.e.c.","final_narrative":"A forklift operator and two spotters were removing a 600-pound pump from a paper machine's virgin pulper. The pump was being lifted by nylon straps, attached to the tines of the forklift, when it became stuck on a pipe flange. The pump disengaged from the housing and started to swing, striking one of the spotters twice in the right leg. The employee received a laceration to the right thigh and another to the right knee, and was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/2019076914"},{"id":"2022076551","event_date":"7/26/2022","employer":"First Quality Tissue, LLC","city":"LOCK HAVEN","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Bruises, contusions","body_part_title":"Nonclassifiable","event_title":"Fall on same level due to tripping over an object","final_narrative":"An employee was ripping paper off a roll. He tripped over a process belt, struck a metal toeboard on a walkway, and landed on his left side. He developed a possible hematoma on his left side and was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/2022076551"},{"id":"2025076943","event_date":"7/17/2025","employer":"First Quality Baby Products, LLC","city":"MACON","state":"GEORGIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations, avulsions, enucleations  unspecified","body_part_title":"Finger or thumb tip(s), nail(s)","event_title":"Injured by object pushed or pulled by person","final_narrative":"An employee was loading a glue drum and pushing the glue drum into the loader while the drum was still elevated on the cart. The employee's hand was caught between the drum and the loader and their fingertip was pinched by the lid of the glue drum, resulting in amputation to the fingertip.","canonical_url":"https://api.morvs.ai/workplace-injury/2025076943"},{"id":"2020065178","event_date":"6/4/2020","employer":"First Quality Retail Services","city":"KING OF PRUSSIA","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Heat (thermal) burns, unspecified","body_part_title":"Fingertip(s)","event_title":"Contact with hot objects or substances","final_narrative":"An employee was draining glue from melted adhesive. The glue severely burned his fingertip and he was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/2020065178"},{"id":"2024065795","event_date":"6/28/2024","employer":"First Quality Baby Products, LLC","city":"MACON","state":"GEORGIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Rib(s), oblique area","event_title":"Caught, entangled in running powered equipment  normal operation","final_narrative":"An employee was cleaning debris off the floor using a cleaning cloth. As the employee was on the floor wiping the debris, the commercial washing machine was started and the injured employee was pinned between the spoke and the frame of the machine, resulting in a fractured rib.","canonical_url":"https://api.morvs.ai/workplace-injury/2024065795"},{"id":"2015041817","event_date":"4/7/2015","employer":"First Quality Tissue, LLC","city":"LOCK HAVEN","state":"PENNSYLVANIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was working on a line that manufactured two-ply paper towels in the converting area.  While attempting to rethread a sheet to create the two-ply, he fingers got pinched between two rollers. He sustained a laceration of the third and fourth digits and a partial amputation of the distal tips; no digits were fully amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/2015041817"},{"id":"20231211621","event_date":"12/25/2023","employer":"First Quality Baby Products, LLC","city":"MACON","state":"GEORGIA","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"On 12/25/2023, at approximately 1:00 PM, a converting pulp mill was plugged up. An employee was going to use compressed air to clean the machine. He thought he dropped a baffle behind the teeth of the machine. When he reached for the baffle, his cut-resistant glove was caught by the teeth (blades). The employee sustained a laceration and partial amputation to the right index finger.","canonical_url":"https://api.morvs.ai/workplace-injury/20231211621"},{"id":"20201211698","event_date":"12/14/2020","employer":"FIRST QUALITY PRODUCTS INC","city":"MC ELHATTAN","state":"PENNSYLVANIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was inspecting a pulp hoist. The hoist was activated and the employee's right index finger was crushed between the lower stop of the hoist and the hoist case itself. The fingertip was partially amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/20201211698"},{"id":"20181111861","event_date":"11/17/2018","employer":"First Quality Tissue, LLC","city":"LOCK HAVEN","state":"PENNSYLVANIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Caught in or compressed by equipment or objects, unspecified","final_narrative":"An employee was replacing a fabric sheet on a paper towel machine. The employee removed a pin on the winch and was checking to see if the machine was lined up when the employee's finger was caught by a moving part. The finger was partially amputated at the middle knuckle.","canonical_url":"https://api.morvs.ai/workplace-injury/20181111861"},{"id":"20191111828","event_date":"11/13/2019","employer":"First Quality","city":"KING OF PRUSSIA","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Crushing injuries","body_part_title":"Hand(s), unspecified","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was cleaning drum rollers. The rollers spun and the employee's hand was pulled in and crushed.","canonical_url":"https://api.morvs.ai/workplace-injury/20191111828"},{"id":"20171010331","event_date":"10/28/2017","employer":"First Quality Enterprises, Inc.","city":"KING OF PRUSSIA","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee reached into a recycling machine to clear a jam and suffered lacerations and fractures to two fingers and the thumb of the right hand. The machine was not locked out at the time.","canonical_url":"https://api.morvs.ai/workplace-injury/20171010331"},{"id":"20171010155","event_date":"10/23/2017","employer":"First Quality Maintenance II LLC","city":"NEW YORK","state":"NEW YORK","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Nonclassifiable","event_title":"Struck by falling object or equipment, n.e.c.","final_narrative":"An employee was placing trash in a bin when aluminum poles that were leaning against the wall fell on him, striking his head and fracturing his vertebrae.","canonical_url":"https://api.morvs.ai/workplace-injury/20171010155"},{"id":"2016010119","event_date":"1/7/2016","employer":"First Quality Products, Inc.","city":"HAZLETON","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Crushing injuries","body_part_title":"Hand(s) and arm(s), n.e.c.","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee entered the slitter machine area to cut off a piece of material. The machine was running at the time.  The employee's left hand and forearm were crushed between two rollers on the machine, requiring hospitalization.","canonical_url":"https://api.morvs.ai/workplace-injury/2016010119"},{"id":"2015010233","event_date":"1/7/2015","employer":"First Quality Baby Products, LLC","city":"MACON","state":"GEORGIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Contact with objects and equipment, unspecified","final_narrative":"On 01/07/15 at 6:45 pm, an employee's  middle index finger was amputated while unclogging a pipe of the dust collector system.","canonical_url":"https://api.morvs.ai/workplace-injury/2015010233"},{"id":"2020010788","event_date":"1/24/2020","employer":"FIRST QUALITY TISSUE LLC","city":"LOCK HAVEN","state":"PENNSYLVANIA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was clearing a jam in a lamination glue filter. The pneumatic ball valve actuated, catching the employee's left middle finger and amputating the fingertip.","canonical_url":"https://api.morvs.ai/workplace-injury/2020010788"}]}