{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.morvs.ai/api/v1/osha/sir/check?name=Integrity%20Services%2C%20LLC","name":"Integrity Services, LLC","_source":{"data_provider":"AI Analytics","brand_name":"MORVS","brand_url":"https://morvs.ai/","data_provider_url":"https://api.morvs.ai","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-11-23T11:41:10.997Z"},"summary":{"total_severe_injuries":3,"amputations":0,"hospitalizations":3,"eye_losses":0},"top_body_parts":[{"body_part_title":"Multiple body parts, n.e.c.","n":1},{"body_part_title":"Lower leg(s)","n":1},{"body_part_title":"Chest, except internal location of diseases or disorders","n":1}],"recent_reports":[{"id":"2020032058","event_date":"3/3/2020","employer":"Integrity Services, LLC","city":"STANTON","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Avulsions, enucleations","body_part_title":"Lower leg(s)","event_title":"Struck by swinging or slipping object, other than handheld, n.e.c.","final_narrative":"Employees were laying down an 8\" drill collar from the catwalk using the main rig hoist. During this, the injured employee was placing a 3x6 wooden board under the collar. When the collar came in contact with the board, it caused the end of the board to rise up, partially degloving the employee's left shin that required a skin graft.","canonical_url":"https://api.morvs.ai/workplace-injury/2020032058"},{"id":"20231211112","event_date":"12/5/2023","employer":"Cleveland Integrity Services, LLC","city":"PORT ARTHUR","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Second degree heat (thermal) burns","body_part_title":"Multiple body parts, n.e.c.","event_title":"Fire, unspecified","final_narrative":"An employee was performing oversight for the welding of a pipeline launcher door on a construction project. Two welders were performing arc welding, one on the interior diameter of the pipeline launcher door, and the other on the outside diameter of the launcher door when a flash fire occurred. The injured employee sustained first- and second-degree burns to the face, neck, back, and hands.","canonical_url":"https://api.morvs.ai/workplace-injury/20231211112"},{"id":"2018011020","event_date":"1/31/2018","employer":"Integrity Services, LLC","city":"MIDLAND","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Internal injuries to organs and blood vessels of the trunk","body_part_title":"Chest, except internal location of diseases or disorders","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was tripping pipe (drilling the pipe down) and screening a drill collar into a stump. He and another employee pushed the tongs into the spinning pipe. The tongs then bit back, crushing him between the tongs and the derrick leg. He received fractures to his upper torso and punctured both lungs.","canonical_url":"https://api.morvs.ai/workplace-injury/2018011020"}]}