{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.morvs.ai/api/v1/osha/sir/check?name=Invista%20S.A.R.L","name":"Invista S.A.R.L","_source":{"data_provider":"AI Analytics","brand_name":"MORVS","brand_url":"https://morvs.ai/","data_provider_url":"https://api.morvs.ai","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-11-29T08:18:44.637Z"},"summary":{"total_severe_injuries":5,"amputations":2,"hospitalizations":4,"eye_losses":0},"top_body_parts":[{"body_part_title":"Nonclassifiable","n":1},{"body_part_title":"Hip(s)","n":1},{"body_part_title":"Fingertip(s)","n":1},{"body_part_title":"Finger(s), fingernail(s), n.e.c.","n":1},{"body_part_title":"Face, unspecified","n":1}],"recent_reports":[{"id":"2018076587","event_date":"7/2/2018","employer":"Invista S.a.r.l.","city":"ORANGE","state":"TEXAS","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was part of a team of four that was moving a large catalyst cartridge using a permanent hoist. The employee was aligning flanges on the bottom of the equipment as it was lowered into place using the hoist. The cartridge was lowered onto the support ring in the cartridge housing while the employee was gripping the support ring with both hands. The employee's fingers were crushed between the cartridge and its housing, causing fracture/amputation injuries to eight fingers.","canonical_url":"https://api.morvs.ai/workplace-injury/2018076587"},{"id":"2017042972","event_date":"4/1/2017","employer":"Invista S.A R.L.","city":"VICTORIA","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Electrical burns, unspecified","body_part_title":"Face, unspecified","event_title":"Direct exposure to electricity, unspecified","final_narrative":"An employee was troubleshooting a switch gear when an arc blast/flash occurred, burning his face.","canonical_url":"https://api.morvs.ai/workplace-injury/2017042972"},{"id":"2017032076","event_date":"3/6/2017","employer":"Invista S.A R.L.","city":"VICTORIA","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Injured by slipping or swinging object held by other person","final_narrative":"Two employees were removing bolts from a flange. One employee was loosening the bolts by hand and another employee was using a pneumatic socket wrench. The wrench has a bar that travels with it and the bar pinched the first employee's finger resulting in amputation of the right index fingertip.","canonical_url":"https://api.morvs.ai/workplace-injury/2017032076"},{"id":"2015020031","event_date":"2/4/2015","employer":"Invista S.A.R.L","city":"WILMINGTON","state":"DELAWARE","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Hip(s)","event_title":"Fall on same level due to slipping","final_narrative":"An employee leaving the work place, slipped and fell on the pavement breaking a hip.","canonical_url":"https://api.morvs.ai/workplace-injury/2015020031"},{"id":"20171111180","event_date":"11/22/2017","employer":"INVISTA S.A.R.L","city":"LA PORTE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Nonclassifiable","event_title":"Struck by discharged object or substance","final_narrative":"An employee was preparing to make piping connections from a heat exchanger to a reactor when a pressurized release of liquid process material occurred. He suffered fractures and was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/20171111180"}]}