{"@context":{"@vocab":"https://schema.org/"},"@type":"ItemList","@id":"https://api.morvs.ai/api/v1/osha/sir/check?name=Trane","name":"Trane","_source":{"data_provider":"AI Analytics","brand_name":"MORVS","brand_url":"https://morvs.ai/","data_provider_url":"https://api.morvs.ai","license":"https://creativecommons.org/publicdomain/zero/1.0/","primary_source":"https://www.osha.gov/severe-injury-reports","generated_at":"2026-11-02T10:22:02.692Z"},"summary":{"total_severe_injuries":34,"amputations":14,"hospitalizations":22,"eye_losses":0},"top_body_parts":[{"body_part_title":"Fingertip(s)","n":7},{"body_part_title":"Finger(s), fingernail(s), n.e.c.","n":3},{"body_part_title":"Toes(s), toenail(s)","n":2},{"body_part_title":"Thigh(s)","n":2},{"body_part_title":"Nonclassifiable","n":2},{"body_part_title":"Multiple body parts, n.e.c.","n":2},{"body_part_title":"Finger(s), fingernail(s), unspecified","n":2},{"body_part_title":"Elbow(s)","n":2}],"recent_reports":[{"id":"2019099898","event_date":"9/21/2019","employer":"Trane","city":"TRENTON","state":"NEW JERSEY","hospitalized":1,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was dismantling equipment for scrap removal. As he was about to remove a motor from a height adjustment rack, the motor slid down the track and struck his left ring finger. He suffered a partial amputation and was hospitalized.","canonical_url":"https://api.morvs.ai/workplace-injury/2019099898"},{"id":"2016098326","event_date":"9/2/2016","employer":"Trane/Ingersoll Rand","city":"PUEBLO","state":"COLORADO","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was installing a frame on a chiller. The employee was positioning two pieces of angle iron to line up the bolt holes when a piece slipped and caught his finger. The left index fingertip was amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/2016098326"},{"id":"2019099587","event_date":"9/13/2019","employer":"Trane/Ingersoll Rand","city":"PUEBLO","state":"COLORADO","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was moving a water box (weighing 160 pounds) and trying to adjust it on a pallet to get it ready for shipping. The injured employee was on the other side of the box trying to move it when her left index finger was caught in between the edge of the water box and the plank on the pallet, resulting in a fingertip amputation.","canonical_url":"https://api.morvs.ai/workplace-injury/2019099587"},{"id":"2025087627","event_date":"8/3/2025","employer":"Trane Technologies Company LLC","city":"VIDALIA","state":"GEORGIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Elbow(s)","event_title":"Slip, trip, stumble while stepping between levels","final_narrative":"An employee was walking up the steps of a work platform and missed a step, striking their toe on the edge of the platform. The employee fell to the metal platform and sustained a fractured elbow that required surgery.","canonical_url":"https://api.morvs.ai/workplace-injury/2025087627"},{"id":"2019088350","event_date":"8/14/2019","employer":"Trane Company","city":"LA CROSSE","state":"WISCONSIN","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Toes(s), toenail(s)","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was turning a unit and brushing welded flanges. The employee's left foot was caught between the lifting table and the surface of the unit, resulting in an amputation to the big toe and the second toe.","canonical_url":"https://api.morvs.ai/workplace-injury/2019088350"},{"id":"2022075924","event_date":"7/7/2022","employer":"Trane U.S., Inc.","city":"LITTLE ROCK AIR FORCE BASE","state":"ARKANSAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures and burns","body_part_title":"Multiple body parts, n.e.c.","event_title":"Other fall to lower level 6 to 10 feet","final_narrative":"On July 8, 2022 at 9:00 a.m., an employee was removing a flow meter located approximately 8.5 feet off the ground on a heated water system. The building was almost complete, so the heating and chilled water systems were operational. The employee was standing on the second rung from the bottom of the 6-foot A-frame ladder that was placed on a 6-foot concrete pad in the locked position. When the meter probe was removed, 180 F water under pressure struck the employee, causing him to fall backward off the ladder and resulting in a fractured ankle and hot water burns to both arms and his back.","canonical_url":"https://api.morvs.ai/workplace-injury/2022075924"},{"id":"2016076053","event_date":"7/6/2016","employer":"Trane, Inc.","city":"TYLER","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"An employee was working on a tool pack that was de-energized when the top of the tool pack (weighing approximately 40 pounds) shifted and came down on his left middle finger, crushing and amputating it.","canonical_url":"https://api.morvs.ai/workplace-injury/2016076053"},{"id":"2019077734","event_date":"7/29/2019","employer":"Trane US, Inc.","city":"GREENVILLE","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Multiple body parts, n.e.c.","event_title":"Other fall to lower level 6 to 10 feet","final_narrative":"An employee was changing a fan motor on an air conditioning unit. The employee fell from the top of the AC unit to the rooftop about 8 feet below, suffering broken ribs and a broken right collarbone.","canonical_url":"https://api.morvs.ai/workplace-injury/2019077734"},{"id":"2015074897","event_date":"7/21/2015","employer":"TRANE","city":"EL PASO","state":"TEXAS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Cuts, lacerations","body_part_title":"Finger(s), fingernail(s), unspecified","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"On July 10, 2015, an employee scratched his left ring finger while placing the door back on an HVAC unit he was servicing. The finger became infected and required hospitalization.","canonical_url":"https://api.morvs.ai/workplace-injury/2015074897"},{"id":"2024064932","event_date":"6/5/2024","employer":"Trane U.S. Inc.","city":"SUMMERDALE","state":"ALABAMA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Thermal burns  second degree","body_part_title":"Hand(s) and arm(s)  n.e.c.","event_title":"Contact with hot objects or substances","final_narrative":"The injured employee was holding a pipe while another employee was un-soldering a line. The line split apart and sprayed residual oil on the employee who was holding the pipe. The injured employee sustained second-degree burns to their left hand and arm.","canonical_url":"https://api.morvs.ai/workplace-injury/2024064932"},{"id":"2018065444","event_date":"6/4/2018","employer":"TRANE U.S. INC.","city":"TYLER","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during maintenance, cleaning","final_narrative":"An employee was troubleshooting a machine when his right index finger and thumb were caught in the tooling clamp, amputating the tips. An energy isolating device was not used during this process.","canonical_url":"https://api.morvs.ai/workplace-injury/2018065444"},{"id":"2019066475","event_date":"6/26/2019","employer":"Trane U.S. Inc. dba The Trane Company","city":"PANAMA CITY","state":"FLORIDA","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Fingertip(s)","event_title":"Caught in running equipment or machinery during regular operation","final_narrative":"An employee was using a vertical belt sander to smooth the edges of a 3-inch by approximately 14-inch piece of steel. The employee used his hands to tilt the back end of the piece of steel upwards in order to sand it at one end when the belt grabbed the piece of steel, causing his left index finger to be caught between the belt and the piece of steel. His left index fingertip was amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/2019066475"},{"id":"2018066203","event_date":"6/22/2018","employer":"Trane US, Inc.","city":"ATTLEBORO","state":"MASSACHUSETTS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Compressed or pinched by shifting objects or equipment","final_narrative":"Two employees were removing the condenser head of a chiller. While the head was suspended, it pivoted, causing one employee's finger to be caught between a bolt and a hole. The finger was amputated.","canonical_url":"https://api.morvs.ai/workplace-injury/2018066203"},{"id":"2017065693","event_date":"6/21/2017","employer":"Trane U.S. Inc.","city":"KENT","state":"OHIO","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Puncture wounds, except gunshot wounds","body_part_title":"Forearm(s)","event_title":"Injured by slipping or swinging object held by injured worker","final_narrative":"An employee was attempting to cut a zip tie on an HVAC water hose with a pocket knife when the knife slipped and stabbed his left forearm.","canonical_url":"https://api.morvs.ai/workplace-injury/2017065693"},{"id":"2023065185","event_date":"6/13/2023","employer":"Trane Commercial Sales Office","city":"ORLAND HILLS","state":"ILLINOIS","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Other burns, unspecified","body_part_title":"Hand(s), unspecified","event_title":"Contact with cold objects or substances","final_narrative":"An employee was performing a pressure check and leak test on a unit when nitrogen gas was released from a valve core removal tool. The nitrogen gas was injected into the employee's right hand, resulting in a burn to the skin, swelling, and pain.","canonical_url":"https://api.morvs.ai/workplace-injury/2023065185"},{"id":"2020054221","event_date":"5/6/2020","employer":"Trane","city":"ATLANTA","state":"GEORGIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Elbow(s)","event_title":"Other fall to lower level, unspecified","final_narrative":"An employee fell from a 10-foot A-frame ladder to the ground while descending. The employee's elbow hit a push cart and their head hit a metal cover on the floor resulting in a fractured elbow and stitches above the eyebrow.","canonical_url":"https://api.morvs.ai/workplace-injury/2020054221"},{"id":"2021053853","event_date":"5/11/2021","employer":"Trane U.S. Inc.","city":"TYLER","state":"TEXAS","hospitalized":0,"amputation":1,"loss_of_eye":0,"nature_title":"Amputations","body_part_title":"Finger(s), fingernail(s), n.e.c.","event_title":"Struck by rolling object or equipment being pushed by injured worker","final_narrative":"An employee was rolling an 800-pound reel of aluminum into the storage area when his left index finger was caught and amputated between two reels.","canonical_url":"https://api.morvs.ai/workplace-injury/2021053853"},{"id":"2016053979","event_date":"5/10/2016","employer":"The Trane Company","city":"LA CROSSE","state":"WISCONSIN","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Hip(s)","event_title":"Other fall to lower level less than 6 feet","final_narrative":"An employee fell off a portable three-step ladder that became unstable, breaking his right hip and requiring surgery.","canonical_url":"https://api.morvs.ai/workplace-injury/2016053979"},{"id":"2024043723","event_date":"4/29/2024","employer":"Trane Supply","city":"PITTSBURGH","state":"PENNSYLVANIA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Lower leg(s)","event_title":"Pedestrian struck by vehicle or object propelled by another vehicle in nonroadway area","final_narrative":"An employee was operating a powered industrial truck (PIT) to move HVAC products when the PIT contacted an adjacent box. The box of material fell from the rack and into the next aisle over, onto another employee who was walking down the aisle. That employee sustained a fractured lower left leg.","canonical_url":"https://api.morvs.ai/workplace-injury/2024043723"},{"id":"2023032482","event_date":"3/20/2023","employer":"Trane U.S. Inc","city":"FORT MITCHELL","state":"ALABAMA","hospitalized":1,"amputation":0,"loss_of_eye":0,"nature_title":"Fractures","body_part_title":"Nonclassifiable","event_title":"Other fall to lower level, unspecified","final_narrative":"An employee was standing on a ladder drilling a hole in the wall to install the control circuit for a new HVAC system. The employee lost his balance and fell to the ground, resulting in a fracture that required hospitalization.","canonical_url":"https://api.morvs.ai/workplace-injury/2023032482"}]}