# AM-241 APPLICATORS FOR INTRACAVITARY IRRADIATION

> **NIH NIH R01** · YALE UNIVERSITY · 1988 · $227,385

## Abstract

Sealed sources of Am-241 emit primarily 60 keV photons; produce
relative dose distributions in water comparable to those from Cs-
137 or Ra-226 sources; and can produce dose rates up to 100 cG/hr
at 1 cm in water.  Am-241 gamma rays can be shielded effectively
by thin layers of high atomic number materials (HVL in 1/8th of
lead) placed on the applicator or inside some body cavities (for
example, hypaque in bladder, barium sulphate in rectum).  These
properties of Am-241 sources open a new approach to optimizing
intracavitary irradiation of various cancers by allowing a
reduction in dose to and volume of irradiated critical organs or
by increasing tumor doses.  The relative ease with which highly
effective shielding is achievable with Am-241 sources would allow
the design and fabrication of partially shielded applicators which
can produce asymmetric dose distributions to allow undirectional
irradiation of localized lesions and would reduce the radiation
exposure to personnel.

This proposal seeks to continue an ongoing investigation into
physical, biological and clinical aspects of intracavitary
irradiation using Am-241 sources.  The current first-generation
gynecological applicator will be modified to produce a second-
generation Am-241 applicator for treatment of primary gynecological
cancers.  Am-241 sources and clinical applicators for intracavitary
irradiation of other disease sites such as rectum, esophagus, etc.,
will be developed.  Dose distributions produced by these
applicators will be measured using ionization chambers and
thermoluminiscent dosimeters in tissue equivalent phantoms.  An
existing dose computation model will be extended to include the
effects of partial shields on the applicators and source-to-source
shielding on the primary and scattered photons using a 3-
dimensional scatter-integration model.

Relative biological effectiveness (RBE) of Am-241 photons as
compared with Ir-192 and I-125 photons will be determined in a rat
solid tumor system for dose rates in the range of 10 to 100 cG/hr
using tumor cell survival and tumor cure as the endpoint.  The
potential benefit for brachytherapy provided by partial shielding
of a critical organ, for example, part of the circumference of the
rectum, will be assessed by studying the early and late radiation
response of partially irradiated rodent intestine.

Ongoing clinical trials for recurrent gynecological cancers using
Am-241 applicators will be continued and clinical studies for
intracavitary irradiation of primary gynecological cancers and
recurrent cancers of the rectum, esophagus, anus, head and neck,
and skin using Am-241 sources will be conducted.

## Key facts

- **NIH application ID:** 3177716
- **Project number:** 2R01CA039044-04A1
- **Recipient organization:** YALE UNIVERSITY
- **SAM.gov UEI:** FL6GV84CKN57
- **Principal Investigator:** RAVINDER NATH
- **Activity code:** R01 (R01, R21, SBIR, etc.)
- **Funding institute:** NIH
- **Fiscal year:** 1988
- **Award amount:** $227,385
- **Award type:** 2
- **Project period:** 1985-01-01 → 1991-06-30

## Primary source

NIH RePORTER: https://reporter.nih.gov/project-details/3177716

## Citation

> US National Institutes of Health, RePORTER application 3177716, AM-241 APPLICATORS FOR INTRACAVITARY IRRADIATION (2R01CA039044-04A1). Retrieved via MORVS 2026-10-25 from https://api.morvs.ai/grant/nih/3177716. Licensed CC0.

---

*[NIH grants dataset](/datasets/nih-grants) · CC0 1.0*