← MSHA accidents

FALL OF ROOF OR BACK

220001220126 · 04/24/2000 · Pine Ridge Coal Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Peabody Energy Corporation
Operator
Pine Ridge Coal Company LLC
Mine
4607908

Narrative

UNINTENTIONAL ROOF FALL NO. 8 BELT NO. 11 CROSSCUT APPROX 6,00 FT OUTBY 1 RIGHT SECTION. FALL SIZE: 25' X 20' X 4'. TYPE ROOF SUPPORTS: 4 FT CONVENTIONAL 5/8"" ROOF BOLTS. NOTE: FALL WAS BREAKE RED OFF AND CLEANED UP AND RESUPPORTED WITH 5'TORQUE TENSIONED BOLTS.