# ELECTRICAL
> MSHA accident `220001580011` · 02/02/2000 · Corbin Collieries, Inc
## Details
- **Degree of injury:** DAYS RESTRICTED ACTIVITY ONLY
- **Classification:** ELECTRICAL
- **Accident type:** Flash burns (electric)
- **Occupation:** Electrician, Lineman
- **Activity:** Machine maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECT.ARC BURN-NOT CONTAC
- **Body part:** MULTIPLE PARTS (MORE THAN ONE MAJOR)
- **Days lost:** —
- **Mine experience:** 0.07 years
## Operator
- **Controller:** Richard F  Baugh
- **Operator:** Corbin Collieries, Inc
- **Mine:** [4406857](https://api.morvs.ai/mine/4406857)
## Narrative

EMPLOYEE WAS WORKING ON BATTERIES WHEN THEY GROUNDED OUT SPARKING A FLASH THAT BURNT HIS LEFT HAND AND FLASH BURNING HIS EYES.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · MORVS · CC0 1.0*