# FALL OF ROOF OR BACK
> MSHA accident `220011200025` · 04/19/2001 · Canyon Fuel Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Arch Resources Inc
- **Operator:** Canyon Fuel Company LLC
- **Mine:** [4201566](https://api.morvs.ai/mine/4201566)
## Narrative

ROOF FALL @ XCUT #6 INTERSECTION 1 TAILGATE ENTRY #1 ( FALL DISCOVERED DURING WEEKLY EXAM). FALL MEASURED 9' HIGH X 16' WIDE X 20' LONG. 72"" RESIN & 10' CABLE BOLTS WERE USED IN AREA. 10' CABL E BOLTS BROKE WITH ANCHOR POPINT STILL INTACT. SEPARATION OF ROOF STRATA DUE TO EXPOSURE OF AIR & WATER OVER TIME, I FEEL IS RESPONSIBLE FOR FALL AT THIS LOCATION.

---