← MSHA accidents

FALL OF ROOF OR BACK

220020110024 · 01/02/2002 · Spartan Mining Company, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Massey Energy Company
Operator
Spartan Mining Company, LLC
Mine
4608808

Narrative

A ROOF FALL OCCURRED AT THE RUBY ENERGY SITE ON 1-2-01. LOCATION WAS #2#5 HEAD LEFT OF XCUT, OUTBY SPAD 922. THE SIZE OF FALL WAS 50' X 20' X 7'. THE AREA ROOF IS SHALE AND HAS A 10"" RIDER SEA M. PRIOR TO THE FALL THEY BOLTED WITH LEFT TORQUE TENS AND 12' CABLE BOLTS. AREA WILL NOT BE REHABILITATED.