# FALL OF ROOF OR BACK
> MSHA accident `220020380059` · 01/05/2002 · Consol Of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol Of Kentucky Inc
- **Mine:** [1517894](https://api.morvs.ai/mine/1517894)
## Narrative

AN UNINTENTIONAL ROOF FALL WAS DISCOVERED IN THE #1 ENTRY BETWEEN #10 AND #11 CROSS CUT IN BY C1 HEAD DRIVE. SIZE OF FALL WAS ESTIMATED TO BE 18' W BY 55' L BY 8' H. AREA HAD BEEN SUPPORTED WITH 4' FULLY GROUTED RESIN BOLTS WITH SUPPLEMENTAL SUPPORT CONSISTING OF 8' CABLE BOLTS. NO INJURIES, NO EQUIPMENT CAUGHT, VENTILATION NOT INTERRUPTED.

---