← MSHA accidents

FALL OF ROOF OR BACK

220020500022 · 02/11/2002 · Solar Sources Underground L L C

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Felson Bowman
Operator
Solar Sources Underground L L C
Mine
1202103

Narrative

AN UNINTENTIONAL ROOF FALL OCCURRED IN THE #1 ENTRY, INBY THE LAST OPEN CROSS CUT, IN THE 001 WORKING SECTION. THE ROOF FALL WAS 42'LONG,18 & 1/2'WIDE AND 6'HIGH. THE ROOF FALL WAS CLEANED UP AND THE AREA WAS RE-SUPPORTED WITH 6'FULLY GROUTED ROOF BOLTS AND INDICATED NO ADVERSE ROOFCONDITIONS. THE ROOF MATERIAL CONSISTED OF FINELY LAMINATED SANDY DARK GRAY SHALE.

Source

Authoritative
MSHA Open Government Data
Machine