← MSHA accidents

FALL OF ROOF OR BACK

220020910134 · 03/22/2002 · Addington Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Pittston Company
Operator
Addington Inc
Mine
1517287

Narrative

A PILLAR FALL OCCURRING IN THE #8 ENTRY LIFT 4B CAUSED A DISRUPTION OF REGULAR MINING FOR MORE THAN 1 HOUR. THE FALL WHICH OCCURRED IN BY PERMANENT SUPPORTS WAS ABOVE THE ANCHORAGE ZONE FOR RO OF BOLTS WHICH WERE OUT BY. NO PERSONAL INJURIESOCCURRED AS A RESULT OF THE PILLAR FALL. FALL MEASURED 20' LENGTH 5' WIDTH 5' HIGH. MSHA DIST 6 WAS NOTIFIED AND CONDUCTED AN INVESTIGATION.

Source

Authoritative
MSHA Open Government Data
Machine