AREA FELL BETWEEN #2 & #3 ENTRIES RETURN, 3,000' FROM ACTIVE SECTION. AREA DEVELOPED 5-10-01. ROOF IS SLATE BOLTED WITH 4'& 6' RESIN. FELL RIB TO RIB, 3-4' THICK. THERE IS A 1 INCH RIDER ABOUT 2'-3' UP. FALL IS DIRECTLY ACROSS FROM SPAD 299. FALL WILL NOT BE MOVED.