# FALL OF ROOF OR BACK
> MSHA accident `220040270017` · 01/19/2004 · Long Branch Energy
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4608855](https://api.morvs.ai/mine/4608855)
## Narrative

THE ROOF FALL MEASURED 20' X 55' X 8' AND WAS IN A 4 WAY INTERSECTION WITH WATER SEEPAGE THROUGH A SHALE IMMEDIATE ROOF. THE AREA HAD BEEN BOLTED WITH 48"" LONG 5/8"" DIA. FULLY GROUTED BOLTS W/ 8"" X 8"" X 1"" HOLE PLATES. THE AREA HAD ALSO BEEN SPOT BOLTED WITH 80"" LONG 3/4"" DIA. MECHANICALLY ANCHORED RESIN BOLTS. THE ENTRY IN AN INACTIVE PORTION OF THE MINE. NO DAMAGE TO EQUIP/PERSON

---