# IGNITION OR EXPLOSION OF GAS OR DUST
> MSHA accident `220050330031` · 01/27/2005 · GCC Dacotah Inc
## Details
- **Degree of injury:** DAYS AWAY FROM WORK ONLY
- **Classification:** IGNITION OR EXPLOSION OF GAS OR DUST
- **Accident type:** Contact with hot objects or substances
- **Occupation:** Prep plant foreman, Supervisor, Mill plant supervisor, Kiln supervisor
- **Activity:** Machine maintenance
- **Injury source:** PULVERIZED MINERAL (DUST)
- **Nature of injury:** BURN OR SCALD (HEAT)
- **Body part:** MULTIPLE PARTS (MORE THAN ONE MAJOR)
- **Days lost:** 24
- **Mine experience:** 12.04 years
## Operator
- **Controller:** GCC SAB de CV
- **Operator:** GCC Dacotah Inc
- **Mine:** [3900022](https://api.morvs.ai/mine/3900022)
## Narrative

3 hourly EEs & supervisor were working on Kiln 6 preheat plug up at Stage 3. They'd been lancing upper section for about 45 min. They decided to try blaster cannons on floor 5. 1 EE left floor 6 & went to floor 5 to initiate blast. He didn't call on radio to make sure everyone was clear. The injured EEs were standing in front of kiln door when he fired cannon.

---