← MSHA accidents

HOISTING

220051050014 · 04/12/2005 · American Rock Salt Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Joseph G Bucci
Operator
American Rock Salt Company LLC
Mine
3003255

Narrative

Main Production hoist kicked out and would not restart. Electrical system on hoist was checked and discovered that 1100 amp, 1000 volt fuse had blown. A replacement fuse was installed after delivered to mine site at 10:00 p.m. Mine was evacuated because hoist is secondary escapeway.

Source

Authoritative
MSHA Open Government Data
Machine