← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220051860039 · 06/25/2005 · Cumberland Coal Resources LP

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Foundation Coal Corporation
Operator
Cumberland Coal Resources LP
Mine
3605018

Narrative

A FRICTION CAUSED METHANE IGNITION, IT OCCURED ON THE LONGWALL PANEL 50 FACE BETWEEN 171 & 172 SHIELDS. METHANE WAS IGNITED BY FRICTION WHEN THE SHEARER STRUCK A PYRETIC INTRUSION LOCATED BETWEEN THE MAIN COAL SEAM & THE DRAW SLATE DIRECTLY ABOVE A DEGAS HOLE LOCATED 1 1/2 FEET FROM THE MINE BOTTOM. A RED/ORANGE FLAME, 2 - 3' LONG BURNED APPROX. 45 SECONDS BEFORE EXTINGUISHED.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown