# FALL OF ROOF OR BACK
> MSHA accident `220053540013` · 12/19/2005 · KenAmerican Resources Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** KenAmerican Resources Inc
- **Mine:** [1517741](https://api.morvs.ai/mine/1517741)
## Narrative

A roof fall occured in the 1 Main East, intersection of #5 entry at crosscut #60. The fall measured approximately 25'x18'x9'. The area was supported with 6' tension rebar bolts and supplemental support consisting of five (5) 9' mega bolts. An undetected slip was determined to be the cause of the fall.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · MORVS · CC0 1.0*