On 1/27/2006 a roof fall occured on the #1 working section of white queen mine. the fall measured 90' long X 18' wide X 10' thick. no injuries were reported. The fall was cleaned up and re-bolted with 6' fully grouted bolts, 8' and 12' cable bolts.Additional bolts were installed on all sides of fall.