# FALL OF ROOF OR BACK
> MSHA accident `220060680021` · 03/02/2006 · Big Ridge Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peabody Energy Corporation
- **Operator:** Big Ridge Inc
- **Mine:** [1103054](https://api.morvs.ai/mine/1103054)
## Narrative

The intersection fell at 10 + 55  in #3 enty in  the # 4 unit intake the fall was approx. 25' long 20' wide and 6' high. This area was mined 8/6/05. The unit is on retreat

---