← MSHA accidents

FALL OF ROOF OR BACK

220061520009 · 05/25/2006 · Wolf Run Mining LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
International Coal Group Inc (ICG)
Operator
Wolf Run Mining LLC
Mine
4604168

Narrative

An unintentional roof fall has occured on the C-Mains #1 entry, between spad stations 13420 and 13406. Height - 10' Width - 18' Length - 30'. The area was supported by 5' fully grouted resin w/ 20"" pizza pans and 10' cable bolts. No equipment damage or personnel injuries.