# FALL OF ROOF OR BACK
> MSHA accident `220063200004` · 11/10/2006 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.morvs.ai/mine/3301070)
## Narrative

A new roof fall occurred on the South Mains ""B"" beltline between 28 and 29 x-cut. The fall was approx. 8 to 9' high by 18' wide and 60' long.  Area was bolted with 8' Install III bolts and resin, H-beamed with 4"" beams sitting on cribs.  Area was cleaned up and re-supported.  Fall did not obstruct ventilation or escapeways. Cause of this fall was weather deterioration.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · MORVS · CC0 1.0*