# FALL OF ROOF OR BACK
> MSHA accident `220070260015` · 01/24/2007 · Long Branch Energy
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4609073](https://api.morvs.ai/mine/4609073)
## Narrative

Roof fall occured in No. 2 entry near spad No. 725, 800 feet outby active face.  Rock is 90 ft. long x 20 ft. wide and 6 to 8 feet thick.  Area had some roof cracks with water seepage.  Roof was bolted with full grout No. 5 x 48 in. bolts.  Ribs had been timbered on 4 ft. centers.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · MORVS · CC0 1.0*