# FALL OF ROOF OR BACK
> MSHA accident `220071630021` · 05/31/2007 · Consolidation Coal Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consolidation Coal Company
- **Mine:** [4200079](https://api.morvs.ai/mine/4200079)
## Narrative

In 14th West Pillar section in the #5 entry a roof fall occurred at approximately 12:45 pm. It fell 18' wide x 31' long x 6' high.  5' resin bolts were installed during development. The cave buried two Mobile Roof Supports. There were no injuries. Two MSHA inspectors had been in the section observing mining prior to the fall.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · MORVS · CC0 1.0*