# FALL OF ROOF OR BACK
> MSHA accident `220073240020` · 11/16/2007 · Long Branch Energy
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4604955](https://api.morvs.ai/mine/4604955)
## Narrative

A 10' x 19' x 6' high roof fall occurred in No. 1 entry approximately 150 feet inby the return air shaft, 3200 feet from No. 1 Section.  Roof is supported with 48"" resin bolts.  2 cribs were installed prior to the fall.  All entries to the fall are breakered off.

---