← MSHA accidents

FALL OF ROOF OR BACK

220073470039 · 12/04/2007 · Dana Mining Company of PA Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
James L Laurita Jr; Thomas A Laurita
Operator
Dana Mining Company of PA Inc
Mine
3609326

Narrative

A roof fall measuring 17'x30'x7' high was discovered during a rock dust surveyor being conducted during an EOI inspection in the south E panel in the intake air course, #8 entry. #10 xc. The area was bolted w/5' fully grouted bolts. The passage of men and supplies, ventilation or escapeways were not involved.

Source

Authoritative
MSHA Open Government Data
Machine