← MSHA accidents

FALL OF ROOF OR BACK

220082760053 · 09/25/2008 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4403932

Narrative

An unintentional roof fall occurred in the # 1 entry of 6-Mains starting at SS# 3907 extending to SS# 3847 and continuing inby SS# 3847 into the #4 entry of 6-Left panel for approximately 80'. The fall dimensions were approximately 18' w x 6' h x 260' long.

Source

Authoritative
MSHA Open Government Data
Machine