← MSHA accidents

FALL OF ROOF OR BACK

220082940063 · 10/13/2008 · Consol of Kentucky Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol of Kentucky Inc
Mine
1518589

Narrative

An unintentional roof fall was discovered at old #15 belt in the #5 entry @ 33 brk, one brk inby spad 9079. Size: 18'W x 20'L x 4-5'H. The area had been bolted with 4 foot fully grouted resin bolts. No injuries, no equipment caught, ventilation was not interrupted. Fall will not be cleaned up.

Source