← MSHA accidents

FALL OF ROOF OR BACK

220083570042 · 12/18/2008 · ICG Hazard LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
International Coal Group Inc (ICG)
Operator
ICG Hazard LLC
Mine
1518850

Narrative

The above mentioned mine has experienced a non-injury, unintentional roof fall on the #5 conveyor belt at x-cut #10. The fall strata was shale, app. 30 feet in width, app. 23 feet in width and 4 feet thick. 48 Inch fully grouted rods and 10 foot cable bolts was the initial support.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown