← MSHA accidents

FALL OF ROOF OR BACK

220090020041 · 12/21/2008 · Consol of Kentucky Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol of Kentucky Inc
Mine
1518589

Narrative

An unintentional roof fall occurred in the #4 entry at spad #9491. The fall was estimated to be 4 ft high by 18 ft wide by 60 ft long. This area was bolted with 4 ft resin bolts with 10 ft cable bolts in the intersection. No injuries, track & belt was caught, ventilation was not interupted. The fall will be cleaned up.

Source

Authoritative
MSHA Open Government Data