FALL OF ROOF OR BACK

220090890069 · 03/21/2009 · Pine Ridge Coal Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Patriot Coal Corporation
Operator
Pine Ridge Coal Company LLC
Mine
4607908

Narrative

East section, No. 5 Entry (roadway) 80 ft. inby survey station 12968. The fall measured approx. 80ft long x 20ft wide x 5 ft high. Five ft 3/4"" dia. Fully grouted resin roof bolts were in use as primary support.