# HOISTING
> MSHA accident `220092150014` · 07/18/2009 · Lyons Salt Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peter E  Powell
- **Operator:** Lyons Salt Company
- **Mine:** [1400413](https://api.morvs.ai/mine/1400413)
## Narrative

Hoist at the main shaft had power problems - lack of power reaching the hoist itself.  Found through troubleshooting process that a voltage phase monitor (electrical component) had failed.  Replacement of the failed part returned the hoist to service some 2 hours later.  Five miners underground were evacuated out the secondary escape shaft.

---