← MSHA accidents

FALL OF ROOF OR BACK

220092930034 · 10/15/2009 · Bluff Spur Coal Corporation

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Cumberland Resources Corporation
Operator
Bluff Spur Coal Corporation
Mine
4405559

Narrative

A roof fall occurred on the #13 belt line in the #4 entry approx. 2000' outby the face. The fall occurred in the intersection at SS6526 and measured 40'x30'x7'. The area was initially bolted with 48"" x 7/8"" resin grouted rods and 6' cable bolts C2 between rows.