← MSHA accidents

FALL OF ROOF OR BACK

220093620010 · 12/22/2009 · Dana Mining Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
GenPower Holdings LP; James L Laurita Jr
Operator
Dana Mining Company LLC
Mine
4604387

Narrative

The area where the fall occurred is a bleeder travelway for the 3 North Panel. One fall occurred in the intersection at 29 Break along the #1 Entry. The area was bolted on advance with 6' fully grouted resin bolts. Some areas around the fall were cribbed previously. Fall varies from 6 to 7 feet in height, and 17 feet wide by 18 feet long. Approximately 500' of cover.

Source

Authoritative
MSHA Open Government Data
Machine