← MSHA accidents

FALL OF ROOF OR BACK

220102290009 · 08/10/2010 · American Energy Corporation

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Robert E Murray
Operator
American Energy Corporation
Mine
3301070

Narrative

Roof fall No. 2 entry to xcut No. 3 was discovered. Fall was approx. 30 feet long by 18 feet wide by 9 feet high. Area was bolted with Install III bolts with resin assisted, with bacon straps and wire mesh screen. Fall was caused by deterioration due to weathering.

Source

Authoritative
MSHA Open Government Data
Machine