← MSHA accidents

FALL OF ROOF OR BACK

220102930007 · 10/11/2010 · Big Ridge Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Peabody Energy Corporation
Operator
Big Ridge Inc
Mine
1103054

Narrative

An unintentional roof fall occurred on the 4C neutral entries at #8 entry 9+80 1st. south sub-main off east sub-main. It measured 25'x 25'x6'. It did not affect ventilation, passage of men or cause personal injury. The area will not be cleaned up. It had been supported with 6 foot fully grouted roof bolts.