Unplanned roof fall was discovered in the Old #1 Panel in #4 entry. The fall was outby spad # 1073 for 3 crosscuts. Fall was approx. 19 ft in width, 300 ft length and 10 ft in height. Area was developed in 7/2009. No injuries, entrapment or equipment involved. No escape way, ventilation or travel way affected.