← MSHA accidents

HOISTING

220120260016 · 01/23/2012 · Morton Salt Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
K+S Aktiengesellschaft
Operator
Morton Salt Inc
Mine
3301993

Narrative

Towards the end of the shift the Dynamic Breaking Contactor on the hoist was not working properly. This shut the hoist down creating an evacuation situation due to not have 2 escape ways to surface. Mine Evacuated with no injuries or other problems. The contactor was cleaned and the hoist was back in service at 13:00 HRs.