← MSHA accidents

FALL OF ROOF OR BACK

220121500026 · 05/24/2012 · M-Class Mining LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Coalfield Transport Inc; Foresight Energy/ Murray Energy
Operator
M-Class Mining LLC
Mine
1103189

Narrative

Roof fall at x-cut 111 on the Headgate #1 unit between the number 2 and #3 entry in the x-cut. It did not block the ventilation or the travel past it. The fall measured about 18 feet wide by 20 feet long, and fell out about 8 to 9 feet high. We set more standing support under and around this area. In the form of cans.