← MSHA accidents

FALL OF ROOF OR BACK

220121710041 · 06/18/2012 · ICG Hazard, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Arch Resources Inc
Operator
ICG Hazard, LLC
Mine
1518991

Narrative

This mine has experienced a non-injury un-intentional roof fall outby the working section. The fall occurred on the intake of Six North which leads to 001 section. The fall is approximately 9 feet thick, 60 feet long and 20 feet wide. This area was initially supported with 60 inch fully grouted rods and 8 foot cable bolts. Laminated shale gave way from deterioration.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown