← MSHA accidents

FALL OF ROOF OR BACK

220122540027 · 08/27/2012 · Midland Trail Energy LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Patriot Coal Corporation
Operator
Midland Trail Energy LLC
Mine
4609297

Narrative

An unintentional roof fall occured in the face of the #6 entry on Rattlesnake section at #61 cross-cut on Rattlesnake #2 belt. The fall measured approximately 55 ft long x 20 ft wide x 8 ft high. The surrounding area was bolted with 4 ft resin bolts.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown