← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220132830058 · 09/27/2013 · Carmeuse Lime Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Carmeuse Holding SA
Operator
Carmeuse Lime Inc
Mine
3301184

Narrative

At 11:41 am on 9/27/13 the kiln system lost I/O communication causing an unplanned shutdown. The system was restarted @ 11:57 am. At 12:00 pm an ignition occurred in the primary air fan of the solid fuel handling system causing an explosion. The solid fuel handling system was shut down & inspected. No personal injuries occurred & limited damage to only the primary air fan housing.