← MSHA accidents

FALL OF ROOF OR BACK

220142190016 · 07/27/2014 · Bowie Resources LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Wolverine Fuels LLC
Operator
Bowie Resources LLC
Mine
0504591

Narrative

On 7/27/14 2-feet to 2.5 sagged onto the top of the longwall stage loader and prevented the loader from advancing normally. The area of sagging roof was approx. 4-feet wide by 70-feet long. The #3 entry of the B-15 headgate panel had been supported with 8-foot fully grouted resin bolts on 5-foot centers with steel roof mesh and cable truss bolts on 5-foot centers.

Source

Authoritative
MSHA Open Government Data
Machine