← MSHA accidents

FALL OF ROOF OR BACK

220152750019 · 10/01/2015 · South Central Coal Company, Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
CraKol Energy LLC
Operator
South Central Coal Company, Inc.
Mine
3402080

Narrative

2nd S.Panel#2 Entry x-c9, roof fall was found intersection. Around 45ft x 25ft x 8-10ft hi in return airway where no one works or travels. This is same area last fall at x-c8 happened. The area was considered bad 9/1/2015 and lifeline rerouted extra support installed. Area originally bolted 8ft full grout rebar bolts & cable bolts in intersection. The ventilation not affected.

Source

Authoritative
MSHA Open Government Data
Machine