← MSHA accidents

HOISTING

220173040020 · 10/24/2017 · Mountain Coal Company, L.L.C.

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Arch Resources Inc
Operator
Mountain Coal Company, L.L.C.
Mine
0503672

Narrative

Upon daily hoist inspection, the hoist computer system was malfunctioning which prevented the operation of the hoist. It was determined that the battery backup caused the problem. The battery backup was disconnected and hoist functions returned. The hoist was not repaired within 30 minutes.