← MSHA accidents

FALL OF ROOF OR BACK

220181730022 · 06/19/2018 · Consol Pennsylvania Coal Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol Pennsylvania Coal Company LLC
Mine
3607230

Narrative

A unintentional roof fall occurred in the 6 South area of the mine at 5 x-cut, in the #7 entry. The fall was caused by adverse geological conditions in this area. The fall measured approx. 63 ft long and 10ft high.

Source

Authoritative
MSHA Open Government Data
Machine