IGNITION OR EXPLOSION OF GAS OR DUST

220183310012 · 11/11/2018 · CEMEX Construction Materials Pacific, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Cemex S A
Operator
CEMEX Construction Materials Pacific, LLC
Mine
0405701

Narrative

CO sensor at 50 ton coal bin quit working and unknown to the operator. The operator ran the coal bin empty in order to perform repairs at the drive sprocket for the screw. There was no ventilation in the system and the agitator was not running causing material accumulation at the bottom of the bin. Co monitor failed giving a false reading pre and post explosion. No injuries.