← MSHA accidents

FALL OF ROOF OR BACK

220201600010 · 06/04/2020 · Wilson Creek Energy LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Quintana Capital Group GP Ltd
Operator
Wilson Creek Energy LLC
Mine
3609893

Narrative

the 4 right area had a roof fall approx. 20' wide X 100' long X unknown Height. #4 entry 1 cross cut inby SS 3751 fall continued inby for 100'. Fall was reported at 2:08PM. Area was bolted with 4' fully grouted bolts. ""No bed separation or visible defects in the roof in this area. Cause of the roof fall is unknow.""

Source

Authoritative
MSHA Open Government Data
Machine