← MSHA accidents

FALL OF ROOF OR BACK

220211020008 · 04/05/2021 · Consol Pennsylvania Coal Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol Pennsylvania Coal Company LLC
Mine
3607416

Narrative

An unintentional roof fall occurred in the H1TG section at 49 wall in the 1 to 2 crosscut into #2 entry migrating into 2 to 3 entry. The fall measured approximately 66 Long x 24 Wide x 16 High. No injuries resulted from the accident. The immediate roof consisted of laminated shale material plus adverse geological conditions contributed to the failure.

Source

Authoritative
MSHA Open Government Data
Machine